Virtual Ethernet Application Guide
==================================

Table of Contents
-----------------

- `Overview <#overview>`__
- `Example Workflows <#example-workflows>`__

  - `Simple
    Loopback <#dpdk-testpmd-simple-loopback-mode-with-auto-start>`__
  - `PacketGen Dual Instance
    Loopback <#packetgen-dual-instance-loopback>`__

- `FAQ <#faq>`__

Overview
--------

The `Virtual Ethernet architecture <../README.html>`__ supports your
development phases with sample applications that include loopback paths
for bringup and debug of the Virtual Ethernet application and custom CL,
all the way to end-to-end application integration with live traffic.

Virtual Ethernet Application Setup and Use
------------------------------------------

The distinct phases of Virtual Ethernet Application setup and use are:

- Software installation and build
- System setup and device binding (e.g. FPGA and ENI)
- Application setup and start

The next sections walk through the setup and usage phases including
example workflows.

Example Workflows
-----------------

DPDK testpmd simple loopback mode with auto-start
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

This example maximizes PPS for 64B packets with a single vCPU using the
DPDK testpmd application to drive the DPDK SPP PMD and the FPGA SDE IP.
This may be used for streaming CL bringup and performance measurements
in an isolated loopback environment. It runs testpmd in auto-start mode,
sends the first burst of TX packets (32 packets by default), and
displays packet statistics every 3 seconds (including PPS). To exit the
example, use ``ctrl-c``.

Software installation and build phase

.. code-block:: bash

   cd $(SDK_DIR)/apps/virtual-ethernet/scripts
   ./virtual_ethernet_install.py <install_dir>

System setup and device bind phase, e.g. on instance boot

.. code-block:: bash

   sudo fpga-load-local-image -S <fpga-slot> -I <SDE loopback CL AGFI>
   cd $(SDK_DIR)/apps/virtual-ethernet/scripts
   sudo ./virtual_ethernet_setup.py <install_dir>/dpdk <fpga-slot>

Testpmd application setup and start phase

.. code-block:: bash

   cd <install_dir>/dpdk
   sudo ./build/app/dpdk-testpmd -l 0-1  -- --port-topology=loop --auto-start --tx-first --stats-period=3

The testpmd application will display the number of TX-packets RX-packets
sent to/from the SDE. Everything three seconds, the number of TX-packets
and RX-packets will be updated to show the new packet total. In
addition, the packets per second throughput is calculated and updated.

.. code-block:: bash

     ######################## NIC statistics for port 0  ########################
     RX-packets: 28791397   RX-missed: 0          RX-bytes:  1842650496
     RX-errors: 0
     RX-nombuf:  0
     TX-packets: 28791429   TX-errors: 0          TX-bytes:  1842651456

     Throughput (since last show)
     Rx-pps:      4798711          Rx-bps:   2456940768
     Tx-pps:      4798711          Tx-bps:   2456940424
     ############################################################################

Please refer to `DPDK
testpmd <#q-where-can-i-find-dpdk-testpmd-feature-documentation>`__ for
a quick reference guide on the supported testpmd features and the link
to the full testpmd documentation.

PacketGen Dual Instance Loopback
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

This example maximizes PPS for 64B packets with a single vCPU using two
instances to test end-to-end traffic flows.

In the diagram below, the ``red`` line shows the Ethernet frame path
from the **Packet Generator Instance** into the CL streaming application
in the **Virtual Ethernet Instance**. The ``blue`` line shows the
Ethernet frame path from the CL streaming application in the **Virtual
Ethernet Instance** to the **Packet Generator Instance**.

**⚠️ For optimal performance and lowest network latency**, the **Virtual
Ethernet Instance** and the **Packet Generator Instance** should be: -
Created in the same VPC - Launched in the same `cluster placement
group <#q-why-cant-i-launch-instance-type-x-in-a-placement-group-with-an-f2>`__
- Using instance types which `support the Elastic Network
Adapter <#q-what-instance-types-support-enhanced-networking>`__ (ENA
driver) type of Enhanced Networking

Launching instances in a cluster placement group ensures they are placed
on hardware with shared, high-capacity networking infrastructure,
providing the lowest possible network latency and highest throughput.
This example was tested using an ``f2.48xlarge`` and an ``m5.2xlarge``
as the **Packet Generator Instance**.

.. figure::
   ../../../../_static/sdk/apps/virtual-ethernet/Virtual_Ethernet_Pktgen.jpg
   :alt: Virtual Ethernet Pktgen

   Virtual Ethernet Pktgen

- **Virtual Ethernet Instance**

  - This workflow sets up the DPDK testpmd application for port-to-port
    forwarding through the DPDK ENA PMD, the DPDK SPP PMD and SDE. It
    then runs testpmd in auto-start mode and displays packet statistics
    every 3 seconds (including PPS). To exit testpmd, use ``ctrl-c``.

- **Traffic Generator Instance**

  - The Traffic Generator instance uses pktgen-dpdk to send max PPS
    towards the Virtual Ethernet instance. This example was tested using
    an ``m5.2xlarge`` and an ``f2.48xlarge``.

- **Network Interface Setup**

  - This example workflow places the PacketGen traffic on ``eth1``, and
    reserves ``eth0`` for your SSH sessions and other control plane
    traffic.
  - An additional network interface can be attached via the EC2 “Attach
    Network Interface” workflow. Your new ``eth1`` network interface is
    automatically initialized if you are using Amazon Linux. If you are
    using Ubuntu, please refer to these additional steps to `attach the
    network interface <#ec2-attach-network-interface-workflow>`__. The
    ENI ``DBDF`` (e.g. the PCI Domain:Bus:Device.Function) for your new
    ENI interface is retrieved using this
    `command <#command-to-retrieve-eni-dbdf>`__.

Virtual Ethernet instance
^^^^^^^^^^^^^^^^^^^^^^^^^

Software installation and build phase

.. code-block:: bash

   cd $(SDK_DIR)/apps/virtual-ethernet/scripts
   ./virtual_ethernet_install.py <install_dir>

System setup and device bind phase, e.g. on instance boot

.. code-block:: bash

   sudo fpga-load-local-image -S <fpga-slot> -I <SDE loopback CL AGFI>
   cd $(SDK_DIR)/apps/virtual-ethernet/scripts
   sudo ./virtual_ethernet_setup.py <install_dir>/dpdk <fpga-slot> --eni_dbdf <eth1 ENI DBDF> --eni_ethdev <eth1 ENI ethdev>

Testpmd application setup and start phase

.. code-block:: bash

   cd <install_dir>/dpdk
   sudo ./build/app/dpdk-testpmd -l 0-1  -- --port-topology=chained --auto-start --stats-period=3 --forward-mode=spp-eni-addr-swap

The ``spp-eni-addr-swap`` testpmd forwarding mode swaps the Ethernet MAC
and IP addresses so the Packet Generator instance can receive the
loopback Ethernet frames.

Please refer to `DPDK
testpmd <#q-where-can-i-find-dpdk-testpmd-feature-documentation>`__ for
a quick reference guide on the supported testpmd features and the link
to the full testpmd documentation.

Packet Generator Instance
^^^^^^^^^^^^^^^^^^^^^^^^^

Software installation and build phase

.. code-block:: bash

   cd $(SDK_DIR)/apps/virtual-ethernet/scripts
   ./virtual_ethernet_pktgen_install.py <install_dir>

During installation, dpdk, pktgen-dpdk, dpdk-kmods, and numactl are
cloned, built, and installed in the . The will have

.. code-block:: bash

   dpdk  dpdk-kmods  numactl  pktgen-dpdk

System setup and device bind phase, e.g. on instance boot

.. code-block:: bash

   cd $(SDK_DIR)/apps/virtual-ethernet/scripts
   sudo ./virtual_ethernet_pktgen_setup.py <install_dir> --eni_dbdf <eth1 DBDF> --eni_ethdev <eth1 ENI ethdev>

Packet Generator setup and start phase:

A sample Packet Generator ``pktgen-ena.pkt`` script is provided. You
will need to modify it to work with your F2 instances.

.. code-block:: bash

   cat $(SDK_DIR)/apps/virtual-ethernet/scripts/pktgen-ena.pkt
   set 0 dst mac 12:DD:AB:C2:D3:B8  # set this to Virtual Ethernet instance eth1 mac address
   set 0 src ip 172.31.63.86/24     # set this to the Packet Generator instance eth1 IP address
   set 0 dst ip 172.31.58.142       # set this to the Virtual Ethernet instance eth1 IP address
   set 0 sport 54321
   set 0 dport 51234
   set 0 type ipv4
   set 0 proto udp
   set 0 size 64
   start 0

Similarly a ``pktgen-ena-range.pkt`` script is provided for multiflow
run with a range of parameters. This needs to be modified with
corresponding dest mac address, src and dest ip addresses.

.. code-block:: bash

   cat $(SDK_DIR)/apps/virtual-ethernet/scripts/pktgen-ena-range.pkt
   set 0 type ipv4
   range 0 dst mac start 06:06:5c:8b:30:0d     # set this to Virtual Ethernet instance eth1 mac address
   range 0 dst mac min 06:06:5c:8b:30:0d       # set this to Virtual Ethernet instance eth1 mac address
   range 0 dst mac max 06:06:5c:8b:30:0d       # set this to Virtual Ethernet instance eth1 mac address
   range 0 dst mac inc 00:00:00:00:00:00
   range 0 src ip start 172.31.60.245          # set this to the Packet Generator instance eth1 IP address
   range 0 src ip min 172.31.60.245            # set this to the Packet Generator instance eth1 IP address
   range 0 src ip max 172.31.60.245            # set this to the Packet Generator instance eth1 IP address
   range 0 src ip inc 0.0.0.0
   range 0 dst ip start 172.31.59.180          # set this to the Virtual Ethernet instance eth1 IP address
   range 0 dst ip min 172.31.59.180            # set this to the Virtual Ethernet instance eth1 IP address
   range 0 dst ip max 172.31.59.180            # set this to the Virtual Ethernet instance eth1 IP address
   range 0 dst ip inc 0.0.0.0
   range 0 src port start 1000
   range 0 src port min 1000
   range 0 src port max 1020
   range 0 src port inc 1
   range 0 dst port start 1000
   range 0 dst port min 1000
   range 0 dst port max 1020
   range 0 dst port inc 1
   range 0 size start 4096
   range 0 size min 4096
   range 0 size max 4096
   range 0 size inc 1
   range 0 proto tcp
   enable 0 range
   start 0

When running the below command, with -j option, the packet size can be
set to jumbo frames and try the example run with pkt size 4096

.. code-block:: bash

   cd <install_dir>/pktgen-dpdk
   sudo LD_LIBRARY_PATH=/usr/local/lib/x86_64-linux-gnu ./build/app/pktgen -l 0,1 -n 16 --proc-type auto --log-level 7 --socket-mem 4096 --file-prefix pg -- -T -j -P -m [1].0 -f $(SDK_DIR)/apps/virtual-ethernet/scripts/pktgen-ena.pkt

FAQ
---

Q: What is the AGFI ID for the SDE loopback CL?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The AGFI ID for the SDE loopback CL is found in the
``CL_SDE Example Metadata`` section at the bottom of the
``CL_SDE README``
`here <../../../../hdk/cl/examples/cl-sde/README.html>`__.

Q: Where can I find DPDK testpmd feature documentation?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The full documentation for DPDK testpmd features is found `the DPDK User
Guide <http://dpdk.org/doc/guides/testpmd_app_ug/index.html>`__.

Note that not all of the DPDK testpmd features are supported by the SPP
and ENI PMDs. SPP supports a limited subset of the DPDK Ethernet upper
API (e.g. DPDK eth_dev_ops) to the DPDK application(s) (e.g. testpmd)
for purposes of passing through streaming packets to/from the SDE.

The application examples use testpmd auto-start mode. testpmd also
supports an interactive mode that may be used during debug and test
sessions. Interactive mode is especially useful when running testpmd
within the ``gdb`` debugger. Below is a quick reference guide for some
of the supported testpmd interactive mode commands that may be used with
the application examples.

Q: Can I map multiple ENIs to a SPP?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The simple `PacketGen Dual Instance
Loopback <#packetgen-dual-instance-loopback>`__ example uses a
one-to-one mapping between SPP and ENI as configured via testpmd. Your
custom applications(s) may map multiple ENIs to a SPP as long as your
application follows the DPDK threading model (e.g. ‘lockless’) and the
CL supports Ethernet frames from multiple ENIs.

Q: Can I map different ENIs to different SPP queues?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The simple `PacketGen Dual Instance
Loopback <#packetgen-dual-instance-loopback>`__ example uses a
one-to-one mapping between SPP and ENI as configured via testpmd.
Multiple SPP queues are not yet supported.

Q: What performance should I expect?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The goal of SPP on F2 is to sustain line rate network bandwidth for all
network configurations supported on the AWS FPGA instances.

Q: How does packet drop and flow control work?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Packet drop and flow control characteristics are application specific,
since you are free to use the DPDK drivers and environment in the best
way that suits your specific application.

As an example, let’s assume we have a packet forwarding topology that
directly connects an ENI to an SPP that does not drop any remaining TX
packets after partial TX packet burst has been submitted to ENI. Since
the application is in control of the packet processing, it can flow off
the SPP RX side by asking for fewer RX packets in the next call to the
SPP RX packet burst API. If the ENI TX backpressure condition persists,
the application may stop calling the SPP RX packet burst API. At this
point, SPP will stop processing RX descriptors, the C2H buffer in the
SDE will become full (see the SDE HW Guide
`here <./SDE-HW-Guide.html>`__), and this will backpressure the AXI-Stream
interface (e.g. the SDE will de-assert the ‘ready’ signal on the C2H
AXI-Stream interface). This may then backpressure the SPP TX side, which
is again under application control. If the SPP TX side backpressure
condition persists, the application may stop processing ENI RX packets
and this will eventually cause packet drops on the ENI RX side facing
the network.

Q: How are SDE errors reported?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

On each call to the SPP TX/RX packet burst APIs, the DPDK SPP PMD checks
the SDE write-back TX/RX status. If the SDE write-back status is
non-zero, the SPP PMD takes the following steps:

- Log-info the TX/RX channel SPP driver status variables and the SDE
  status write-back variables
- Log-info the specific SDE error info from the SDE block that
  encountered the error
- Log-info the descriptor ring entries
- Increments the TX/RX sde_error stat
- Log-error and return from the TX/RX status checking method.
- Return 0 packets processed from the SPP TX/RX packet burst APIs
  (e.g. the DPDK TX/RX packet burst APIs return a uint16_t that
  indicates the number of packets that were processed in the current
  call).

Your application should periodically check to see if the TX/RX sde_error
stat is non-zero (e.g. by calling the eth_dev_ops xstats_get API for
error checking in the ``slow-path``). If the TX/RX sde_error stat is
non-zero, your application should take the following error recovery
steps:

- Quiesce all calls to TX/RX packet burst (e.g. discontinue calling
  ``rte_eth_dev tx/rx_pkt_burst``)
- Release all of the SPP queues (e.g. call
  ``eth_dev_ops tx/rx_queue_release``)
- Remove the SPP PCI device (e.g. call ``rte_pci_driver remove``)
- Reload the AGFI using ``fpga-load-local-image`` to ensure the CL is
  fully reset

At this point, the DPDK SPP driver and SDE may be re-initialized as
normal. The SDE is reset during the SPP PCI device probe initialization
step, and the TX/RX queues are re-initialized during the TX/RX queue
setup phase.

Q: What is the minimal packet size supported by AWS FPGA virtual ethernet IP?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

FPGA CL must generate packets with 64Byte or more to meet the Ethernet
minimum frame size requirement.

Q: What is the maximal packet size?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

It is the maximal packet size offered by ENI on your instance (including
the 4-byte CRC).

Q: Should I calculate the Ethernet frame CRC32?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

No, SPP relies on the ENI to check CRC on receive and calculate it on
transmit.

Q: What MAC address should I use for SPP?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The SPP MAC address is normally unused for testpmd port based forwarding
and defaults to all zeroes. The default SPP MAC address may be changed
if needed using the testpmd ‘mac_addr set’ command when using the
testpmd application, or by your custom application using the DPDK APIs.

Note that the SPP and SDE do not perform any modifications to the TX
packets (e.g. from the application to the CL), or the RX packets
(e.g. from the CL to the application). The SDE does not perform any
packet filtering (e.g. based on the packet destination MAC address).

Q: How many TX and RX descriptors are supported?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The number of supported TX and RX descriptors per SPP queue pair is
parameterized within the SDE block and reported by the SDE to SPP via
registers within the SDE block (see the SDE H2C and C2H channels
`here <./SDE-HW-Guide.html>`__). SPP defines a minimum and the maximum
number of descriptors between 64 and 32K. The number of TX and RX
descriptors implemented in the SDE and requested by the DPDK application
in the SPP queue setup phase must be equal, and a power of 2.

Q: How do I configure SPP to use SDE regular or compact descriptors?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The SDE may be built with regular or compact descriptor types (see the
C2H_DESC_TYPE and H2C_DESC_TYPE in the Design Parameters section
`here <./SDE-HW-Guide.html>`__). The SPP PMD also supports regular or
compact descriptor types at compile time via the SPP_USE_COMPACT_DESCS
define within spp_defs.h. The default descriptor type for the SDE and
SPP is ``regular`` to support the full 64-bit DMA addressing. If there
is a mismatch between the SDE and SPP descriptor type build options, the
SPP driver will log an error similar to the following:

Mismatched build options: SDE descriptor type is ``regular``, SPP PMD
descriptor type is ``compact``.

.. code-block:: bash

   PMD: spp_dev_cap_get(): SDE C2H Desc Info(0x00400000), type=regular, is not supported

Mismatched build options: SDE descriptor type is ``compact``, SPP PMD
descriptor type is ``regular``.

.. code-block:: bash

   PMD: spp_dev_cap_get(): SDE C2H Desc Info(0x00800001), type=compact, is not supported

Q: What operating systems are supported?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The Virtual Ethernet application is tested and supported for Linux
operating systems (Amazon Linux and Ubuntu).

Q: I am using the Ubuntu AMI. How do I setup the additional ENI/eth1 interface for the `PacketGen Dual Instance Loopback <#packetgen-dual-instance-loopback>`__ example?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

EC2 Attach Network Interface Workflow
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^

An additional network interface can be attached via the EC2 “Attach
Network Interface” workflow. Your new ``eth1`` network interface is
automatically initialized if you are using Amazon Linux. If you are
using Ubuntu, please execute the following steps:

Use the EC2 Console to view the IP Address and Mac Address of the
additional network interface. The Mac Address ``12:1e:7e:0b:70:2e`` and
IP Address ``172.1.1.22`` are used for illustration purposes.

Create an ``eth1`` specific configuration using the existing ethernet
adapter as a template.

.. code-block:: bash

   sudo vi /etc/netplan/50-cloud-init.yaml
   eth1:
         dhcp4: false
         dhcp6: false
         addresses:
         - 172.1.1.22
         match:
           macaddress: 12:1e:7e:0b:70:2e
         set-name: eth1

Initialize the ``eth1`` interface using ``sudo netplan --debug apply``
and then show the ``eth1`` configuration using ``ifconfig``.

.. code-block:: bash

   ifup eth1
   Determining IP information for eth1... done.
   ifconfig eth1
   eth1: flags=4163<UP,BROADCAST,RUNNING,MULTICAST>  mtu 9001
           inet 172.1.1.22  netmask 255.255.240.0  broadcast 172.1.1.255
           inet6 fe80::101e:7eff:fe0b:702e  prefixlen 64  scopeid 0x20<link>
           ether 12:1e:7e:0b:70:2e  txqueuelen 1000  (Ethernet)
           RX packets 10  bytes 1052 (1.0 KiB)
           RX errors 0  dropped 0  overruns 0  frame 0
           TX packets 12  bytes 1416 (1.3 KiB)
           TX errors 0  dropped 0 overruns 0  carrier 0  collisions 0

At this point, the ``eth1`` interface is ready for the setup script(s)
that are described in the `PacketGen Dual Instance
Loopback <#packetgen-dual-instance-loopback>`__ example.

Q: How do I retrieve the ENI DBDF for the additional ENI/eth1 interface that is used in the `PacketGen Dual Instance Loopback <#packetgen-dual-instance-loopback>`__ example?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Command to retrieve ENI DBDF
^^^^^^^^^^^^^^^^^^^^^^^^^^^^

The ENI DBDF for the ``eth1`` interface can be retrieved as follows
using a grep for ``1d0f:ec20`` through the ``lspci`` command output.

.. code-block:: bash

   lspci -D | grep "1d0f:ec20"
   0000:00:03.0 Ethernet controller: Device 1d0f:ec20    # this is eth0
   0000:00:04.0 Ethernet controller: Device 1d0f:ec20    # this is eth1.  The DBDF is 0000:00:04.0

Q: How do I update DPDK and SPP with the Vendor/Device ID for my CL?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Within ``<install_dir>/dpdk/drivers/net/spp`` there is a file called
``spp_ethdev.c``. Your Vendor and Device ID should be added to the
following table in ``spp_ethdev.c`` and then DPDK should be recompiled.

.. code-block:: c

   static const struct rte_pci_id pci_id_spp_map[] = {
           { RTE_PCI_DEVICE(PCI_VENDOR_ID_AMAZON, PCI_DEVICE_ID_SDE_LOOPBACK_CL) },
           { RTE_PCI_DEVICE(<Your Vendor ID>, <Your Device ID>) },
           { .device_id = 0 },
   };

Rebuild DPDK as follows:

.. code-block:: bash

   cd <install dir>/dpdk
   ninja -C build

Within ``<install dir>/dpdk/usertools`` there is a file called
``dpdk-devbind.py``. Your Vendor and Device ID should be added to the
following table in ``dpdk-devbind.py``.

.. code-block:: python

   aws_fpga_sde = {'Class': '05', 'Vendor': '1d0f', 'Device': 'f002',
                 'SVendor': None, 'SDevice': None}
   <your tag> = {'Class': '05', 'Vendor': '<Your Vendor ID>', 'Device': '<Your Device ID>',
                 'SVendor': None, 'SDevice': None}

   network_devices = [network_class, cavium_pkx, avp_vnic, aws_fpga_sde, <your tag>]

You should then run the ``virtual_ethernet_setup.py`` script which will
re-run the ``dpdk-devbind.py`` script to bind DPDK and SPP to your
Vendor and Device Id.

Q: What instance types support Enhanced Networking?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

At the time of writing, compatible instance types are all `Nitro-based
instances <https://docs.aws.amazon.com/AWSEC2/latest/UserGuide/instance-types.html#instance-hypervisor-type>`__
and the following Xen-based instances G3, H1, I3, ``m4.16xlarge``, P2,
P3, P3dn, R4. For more information, see the documentation on `Enhanced
Networking on
Linux <https://docs.aws.amazon.com/AWSEC2/latest/UserGuide/enhanced-networking.html>`__.

Q: Why can’t I launch instance type X in a placement group with an F2?
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

When you launch instances in a cluster placement group, AWS attempts to
launch those instances on hardware which share high capacity networking
infrastructure. It is not always possible to launch heterogeneous
instance types within such a group. This depends on the underlying
arrangement of this physical hardware. If it is not possible to launch
an instance of the desired type in a placement group with an F2, try
using another F2 instance as the packet generator instance. For more
information, see the `documentation on placement
groups <https://docs.aws.amazon.com/AWSEC2/latest/UserGuide/placement-groups.html>`__.

`Back to Home <../../../../index.html>`__